ACC-905 PC PROGRAMMER
For PL2215P, PL2245P, PL2415, PL2445
Page -10-
October 2001
SYSTEM OPTIONS
Scan
The scan section allows for many features to be programmed to tailor the scanning to
your needs.
Scan Enable
Enable channel scanning in the radio
Scan Chan Number
The channel that the user selects to enable scanning.
Scan Speed
The amount of time that the radio looks at each channel. This value is set in millisec-
onds and the default is 50ms. Range is 50ms to 500ms.
Scan Delay
This is the amount of time the the radio will stay on a channel after the carrier has
dropped. This value is set in seconds and the default value is 4 seconds. Range 1 to
30 seconds.
Priority Scan Enable
This Enables the radio to scan to a predefined priority channel. All communications on
the priority channel will override any communications on any other channel.
Note: When using priority scan, the radio will look back to the priority channel peri-
odically. The user may respond to a call while the TX delay has not expired (See
“TX Delay” on page 9). In order to initiate a call, the user must turn the scan func-
tion off by turning the channel selector.
Priority Scan Channel
This is the channel that will be given priority.
Lookback Time
How often the priority channel is looked at. This value is set in seconds and the default
is 4 seconds. Range is .5 to 10 seconds.
Time Out Timer
This is a timer that will limit the time that a user can transmit at any one time.
Time Out Timer Enable
This enables the Time Out Timer.
TX Time Out Time
The amount of time that the radio will enable the user to transmit before timing out and
turning off the transmitter. This value is set in seconds and the default is 180 seconds.
Range is 10 to 2000 seconds.
Time Out Timer Penalty Enable
Once the radio has timed out, this makes the radio wait for a set time before being
able to transmit again. This time is set in seconds and the default is 5 seconds. Range
is 1 to 100 seconds.